Impecca ISFW421824 Manual

Consulte online ou descarregue Manual para não Impecca ISFW421824. Impecca ISFW421824 Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Outdoor Unit

Flex Series Outdoor UnitOwner's ManualCommercialAirConditionersModel: ISMO-4221Thank you for choosing our air conditioner, please read this O

Página 2 - Preface

Flex Series7 Allowable Length and Height Fall of the Refrigerant Pipe Table 7 Allowable Value Fitting Pipe Total length (actual length) of fitting pi

Página 3 - Contents

Flex Series 8 After the pipe is protected well enough, never bend it to form a small angle; otherwise it would crack or break. (3)Wrap the Pipe with T

Página 4 - 1 Safety Precautions

Flex Series9 (2) Calculation of the Additional Refrigerant ChargeAdditional Refrigerant Charge=(ΣLength of Liquid Pipeφ0.375×54+ΣLength of Liquid Pipe

Página 5 - 2 Product Introduction

Flex Series 10 1) The mistake connecting line will result in malfunction. After the electrical wiring working, ensure the wirebetween t

Página 6

Flex Series11 5 Troubleshooting 1) In the event of abnormal conditions (like, stinky smell), please shut off the main power supply immediately andt

Página 7

Flex Series12 6 The conditions listed below are not classified into errors. Table 10 Conditions Causes The unit does not run When restart the unit soo

Página 8 - 4 Installation Instruction

Flex Series13 running next operation Mode conflict COOL or HEAT mode can not be operated When the indoor operating mode conflicts with that of outdoor

Página 9

Flex Series147 Troubleshooting The error code will be displayed on the wired controller and the main board of the outdoor unit The meaning of each err

Página 10

Flex Series15 8 Maintenance 8.2 Drain Pipe Regularly check if the drain pipe is clogged in order to drain condensate smoothly. 8.3 Notice before Seaso

Página 11

Before contacting customer support, please see the troubleshooting guide above. Visit our website to contact us, find answers to Frequently Asked Ques

Página 12

Preface Impecca Flex System adopts the cutting-edge manufacturing technology and takes globalacknowledged, environmental-friendly R410A as

Página 14 - 5 Troubleshooting

Split Air ConditionerModels: ISMI-W182ISMI-W242Thank you for choosing our product.For proper operation, please read and keep this manual carefully. If

Página 15

This appliance is not intended for use by persons (including children) with reduced physical,sensoryor mental capabilities or lack of experience and k

Página 16

Explanation of SymbolsIndicates a hazardous situation that, if not avoided, willresult in death or serious injury.Indicates a hazardous situation that

Página 17 - 7 Troubleshooting

PrecautionsWARNINGDo not connect air conditioner to multi-purpose socket.This appliance can be used by children aged from 8 Operation and MaintenanceI

Página 18 - 8.1 Outdoor heat exchanger

Do not block air outlet or air inlet. It may cause malfunction.remote controller may be broken.Ɣ Power cord is overheating or damaged.Ɣ There’s abnorm

Página 19 -  www.instagram.com/impecca/

Do install the circuit break. If not, it may cause malfunction. of at least 3mm in all poles should be connected in fixed wiring.magnet buckle and hea

Página 20

Installation must be performed in accordance with the persons in order to avoid a hazard.must be properly grounding with specialized grounding device

Página 21 - Split Air Conditioner

The indoor unit should be installed close to the wall.Instructions for installation and use of this product are provided by the manufacturer.Precautio

Página 22

6(Display content or position may be different from above graphics, please refer to actual products)Parts NameIndoor Unitair inletpanelaux.buttonhoriz

Página 23 - Explanation of Symbols

Contents 1 Safety Precautions... 1 2 Product Introduc

Página 24 - Precautions

7Buttons on remote controllerIntroduction for icons on display screen125791110128643123456789101112ON/OFF buttonMODE buttonEXWWRQ)$1EXWWRQ but

Página 25

8Ɣ:KHQVHOHFWLQJDXWRPRGHDLUFRQGLWLRQHUZLOORSHUDWHDXWRPDWLFDOO\DFFRUGLQJWRH[IDFWRU\VHWWLQJ6HWWHPSHUDWXUHFDQ¶WEHDGMXVWHGDQGZLOO

Página 26

9Introduction for buttons on remote controller)$1EXWWRQ43UHVVLQJWKLVEXWWRQFDQVHWIDQVSHHGFLUFXODUO\DVDXWR$872ORZ PHGLXP( ),

Página 27

10Press this button to set clock time. " " icon on remote controller will blink. Press RUEXWWRQZLWKLQVWRVHWFORFNWLPH(D

Página 28

11TEMP button9Introduction for buttons on remote controller%\SUHVVLQJWKLVEXWWRQ\RXFDQVHHLQGRRUVHWWHPSHUDWXUHLQGRRUDPELHQWWHPSHUDWXUHRU

Página 29 - Parts Name

12Function introduction for combination buttonsChild lock function3UHVVDQGVLPXOWDQHRXVO\WRWXUQRQRUWXUQRIIFKLOGORFNIXQFWLRQ:KHQch

Página 30 - Buttons on remote controller

131.After putting through the power, press "ON/OFF" button on remote controller toturn on the air conditioner.2.Press "MODE" butto

Página 31

14Emergency operationIf remote controller is lost or damaged, please use auxiliary button to turnon or turn off the air conditioner. The operation in

Página 32 - KRUL]RQWDOORXYHUVVWRSV

15Clean and Maintenance1234Open panelPull out the panel to a certain Ɣ8VHGXVWFDWFKHURUZDWHUWRWKHZDWHUEHORZć) to clean LWDQGWKHQ

Página 33

16Clean and maintenance1. Check whether air inlets and air outlets are blocked.2. Check whether circuit break, plug and socket are in good condition.4

Página 34

Flex series1 1 Safety PrecautionsThis is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messag

Página 35 - Child lock function

17Malfunction analysisGeneral phenomenon analysisPlease check below items before asking for maintenance. If the malfunction stillFDQ¶WEHHOLPLQDWHG

Página 36 - Operation guide

18Malfunction analysisƔ3RZHUIDLOXUH"Ɣ,VSOXJORRVH"Ɣ Circuit break trips off or fuse is burnt out?Ɣ:LULQJKDVPDOIXQFWLRQ"Ɣ8QLW

Página 37 - Clean and Maintenance

19Malfunction analysisPhenomenon Check items SolutionOdours are emittedƔ:KHWKHUWKHUH’s odour source, such as furniture and cigarette, etc.Ɣ(OL

Página 38

20Malfunction analysisError codeE5U8H6C5F1F2TroubleshootingIt can be eliminated after restarting the unit. If not, please It can be eliminated after r

Página 39 - Clean and maintenance

21Installation dimension diagramAt least 250cmAt least 15cmAt least 300cm6SDFHWRWKHÀRRUSpace to the ceilingSpace to the obstructionAt least 15cmAt

Página 40 - Malfunction analysis

22Selection of installation locationBasic requirementInstalling the unit in the following pla-ces maycause malfunction. If it is un-avoidable, please

Página 41

23Requirements for electric connectionSafety precautionGrounding requirement1. Must follow the electric safety regulations when installing the unit.ci

Página 42

24Installation of indoor unitStep one: choosing installation locationStep two: install wall-mounting framerm it with the client.1. Hang the wall-mount

Página 43 - ON 10s OFF 0.5s

251. Aim the pipe joint at the correspondingbellmouth.2. Pretightening the union nut with hand.3. Adjust the torque force by referring to the followin

Página 44 - Space to the obstruction

26nection pipe with insulating pipe, andinsulating pipe1. Connect the drain hose to the outlet pipe ofoutletpipedrain hosedrain hosetapeoutlet pipedra

Página 45 - Tools for installation

Flex Series2 Impecca is not responsible of personal injury or equipment damage caused by improper insta llation and commission, unnecessa

Página 46 - Grounding requirement

274. Put wiring cover back and then tighten the screw.5. Close the panel.Installation of indoor unitNote:Ɣ All wires of indoor unit and outdoor unit s

Página 47 - Installation of indoor unit

28Installation of indoor unitStep eight: bind up pipe1. Bind up the connection pipe, power cord and drain hose with the band.indoor unitgaspipeindo

Página 48

29Check after installationTest operationƔ&KHFNDFFRUGLQJWRWKHIROORZLQJUHTXLUHPHQWDIWHU¿QLVKLQJLQVWDOODWLRQItems to be checked Possible ma

Página 49

301. Standard length of connection pipeƔPPP4. The additional refrigerant oil and refrigerant charging required after prolongingconnecti

Página 50

31Additional refrigerant charging amount for R22, R407C, R410A and R134aDiameter of connection pipeLiquid pipe(mm) Gas pipe(mm)ĭĭRUĭĭRUĭ

Página 51

32Pipe expanding methodNote:Improper pipe expanding is the main cause of refrigerant leakage. Please expandthe pipe according to the following steps:A

Página 52 - Test operation

Wired Controller 1 Displaying PartFig1.1.1 Outline of wired controller1.1 LCD Display of Wired ControllerFig.1.1.2 LCD display33If the product you bou

Página 53

1.2 Instruction to LCD DisplayTable 1.1No. Symbols Description1Swing function2Air exchange function (this function is yet unavailable for this unit).3

Página 54

2 Buttons2.1 Layout of Buttons2.2 Functions of ButtonsTable 2.1No. Name Function1 Enter/Cancel Function selection and cancellation.2 Ÿķ .Running tempe

Página 55 - Pipe expanding method

3 Operation Instructions3.1 On/OffPress On/Off to turn on the unit and turn it off by another press.Note: The state shown in Fig.3.1.1 indicates the “

Página 56 - Wired Controller

Flex Series3 2.2 Combinations for outdoor and indoor units Wall MountedIndoor UnitWall MountedIndoor UnitCassettle TypeIndoor UnitFloor/ Ceiling Indoo

Página 57

3.4 Fan SettingUnder the “On” state of the unit, press Fan and then fan speed of the indoor unit will changecircularly as shown in Fig.3.4.1.Low Middl

Página 58

Timer on setting under the “Off” state of the unit is shown as Fig.3.5.2.Fig.3.5.2 Timer on Setting under the “Off” State of the UnitTimer range: 0.5

Página 59

3.6 Swing SettingSwing On: Press Function under on state of the unit to activate the swing function. In this case,Swing Off: When the Swing function

Página 60

3.7 Sleep SettingSleep on: Press Function under the On state of the unit till the unit enters the Sleep settingSleep off: When the Sleep function is a

Página 61

3.8 Turbo SettingTurbo function: The unit at the high fan speed can realize quick cooling or heating so that theroom temperature can quickly approach

Página 62

3.9 E-heater SettingE-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to beOnce the wired controller or the rem

Página 63

3.10 Blow SettingBlow function: After the unit is turned off, the water in evaporator of indoor unit will beautomatically evaporated to avoid mildew.I

Página 64

3.11 Other Functionsa. LockUpon startup of the unit without malfunction or under the “Off” state of the unit, press Ÿ and źatthe same time for 5s til

Página 65

168 91073 452Fig.4.2Fig.4.2 shows the installation steps of the wired controller, but there are some issues that needyour attention.1) Prior to the in

Página 66

and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm,otherwise the communication of the unit will probably work a

Página 67

Flex Series 2.4 The range of production working temperature Table 3 Cooling Working range Outdoor temperature 0~118℉ Heating Working range Outdoor t

Página 68

Table 5.1 Meaning of Each ErrorErrorErrorCodeErrorErrorCodeReturn air temperature sensor open/short circuited F1 Drive board communication error P6ev

Página 69

CUSTOMER SUPPORTBefore contacting customer support, please see the troubleshooting guide above. Visit our website to contact us, find answers to Frequ

Página 70

© 2016 Impecca, a division of LT Inc., Wilkes Barre, PA.

Página 71 - www.facebook.com/Impecca/

Flex Series5 3.3 Piping Connection The maximum pipe length is shown in the following table. When the distance between units (piping length) is ou

Página 72

Flex Series6 4.2 Installation of the Connection Pipe Connecting piping for indoor unit and outdoor unit are in manifold mode. (As shown below).

Comentários a estes Manuais

Sem comentários